From da9df9d46ed3fc50e0c03497bd9f76b8aa1a4595 Mon Sep 17 00:00:00 2001
From: chenluhua1980 <Chenluhua@qq.com>
Date: 星期三, 14 一月 2026 15:37:48 +0800
Subject: [PATCH] 1.修复以下问题: 作业前置条件不足导致 PJ 验证失败:onPRJobMultiCreate 调 CMaster::setProcessJobs,CProcessJob::validate 要求“当前没有其它 PJ”(issue 1000),且 carrierPresent/slotUsable 必须为真。只要本地还有未结批的 PJ/CJ 或载具/槽位状态未就绪(ID 未绑、Slot 未使能),Host 发送的 CreateMultiPJ 会直接被丢弃(返回 size=0),但当前代码没有向 Host 回 ACK/NAK,Host 会误以为创建成功。

---
 SourceCode/Bond/x64/Debug/AlarmList.csv |    4 +---
 1 files changed, 1 insertions(+), 3 deletions(-)

diff --git a/SourceCode/Bond/x64/Debug/AlarmList.csv b/SourceCode/Bond/x64/Debug/AlarmList.csv
index 08cd213..61a6625 100644
--- a/SourceCode/Bond/x64/Debug/AlarmList.csv
+++ b/SourceCode/Bond/x64/Debug/AlarmList.csv
@@ -1,3 +1 @@
-锘縉o,UNIT ID,UNIT NO,Alarm Level,Alarm Code,AlarmID,Alarm Text,Description
-1,EFEM(ROBOT)-EFEM,,0,2,100,Fatal communication error in the ACLS receive loop. Please reboot MCC., Fatal communication error in the ACLS receive loop. Please reboot MCC.
-2,Load Port 1-EFEM,,1,1,101,"Must check substrate location due to the failure of ACLS operation <%s> ; To protect glass, a dummy glass has been created"," Must check substrate location due to the failure of ACLS operation <%s> ; To protect glass, a dummy glass has been created"
\ No newline at end of file
+No,UNIT ID,UNIT NO,Alarm Level,Alarm Code,AlarmID,Alarm Text,Description
1,EFEM,100,0,0,1000,机器人CCLink链接异常,"请检查接线,断电重启"
2,EFEM,101,0,0,1001,相机CCLink链接异常,"请检查接线,断电重启"
3,EFEM,102,0,0,1002,静电测试CCLink链接异常,"请检查接线,断电重启"
4,EFEM,103,0,0,1003,,
5,EFEM,104,0,0,1004,,
6,EFEM,105,0,0,1005,,
7,EFEM,106,0,0,1006,,
8,EFEM,107,0,0,1007,,
9,EFEM,108,0,0,1008,,
10,EFEM,109,0,0,1009,,
11,EFEM,110,0,0,1010,总进气气压异常,请检测进气
12,EFEM,111,0,0,1011,总真空气压异常,请检测真空
13,EFEM,112,0,0,1012,LP真空异常,检测真空
14,EFEM,113,0,0,1013,离子风棒压空异常,请检测进气
15,EFEM,114,0,0,1014,机器人真空异常,请检测真空
16,EFEM,115,0,0,1015,急停被按下,请检查急停按钮
17,EFEM,116,0,0,1016,,
18,EFEM,117,0,0,1017,,
19,EFEM,118,0,0,1018,,
20,EFEM,119,0,0,1019,,
21,EFEM,120,0,0,1020,安全门打开,请检查安全门
22,EFEM,121,0,0,1021,正面左门打开中,请检查安全门
23,EFEM,122,0,0,1022,正面右门打开中,请检查安全门
24,EFEM,123,0,0,1023,侧面左门打开中,请检查安全门
25,EFEM,124,0,0,1024,侧面右门打开中,请检查安全门
26,EFEM,125,0,0,1025,背面左门打开中,请检查安全门
27,EFEM,126,0,0,1026,背面右门打开中,请检查安全门
28,EFEM,127,0,0,1027,,
29,EFEM,128,0,0,1028,,
30,EFEM,129,0,0,1029,,
31,EFEM,130,0,0,1030,,
32,EFEM,131,0,0,1031,"Port1_E84流程异常,OHT_TR_REQ_ON信号超时",请检查OHT或者E84线缆
33,EFEM,132,0,0,1032,"Port1_E84流程异常,OHT_BUSY_ON信号超时",请检查OHT或者E84线缆
34,EFEM,133,0,0,1033,"Port1_E84流程异常,OHT_COMPT_OFF信号超时",请检查OHT信号或者E84线缆
35,EFEM,134,0,0,1034,,
36,EFEM,135,0,0,1035,,
37,EFEM,136,0,0,1036,,
38,EFEM,137,0,0,1037,,
39,EFEM,138,0,0,1038,,
40,EFEM,139,0,0,1039,,
41,EFEM,140,1,0,1040,"Port1_E84流程停止,OHT_VALID信号异常",请检查OHT信号或者E84线缆
42,EFEM,141,1,0,1041,"Port1_E84流程停止,光栅被遮挡或者急停被拍",请检查光栅信号急停
43,EFEM,142,1,0,1042,"Port1_E84流程停止,OHT_取或放FOUP超时","OHT_BUSY后未在规定时间内取走FOUP,请检查OHT或者核对LP状态"
44,EFEM,143,1,0,1043,"Port1_E84流程停止,OHT_BUSY_OFF或者TR_REQ_OFF信号超时",请检查OHT信号或者E84线缆
45,EFEM,144,0,0,1044,,
46,EFEM,145,0,0,1045,,
47,EFEM,146,0,0,1046,,
48,EFEM,147,0,0,1047,,
49,EFEM,148,0,0,1048,,
50,EFEM,149,0,0,1049,,
51,EFEM,150,0,0,1050,"Port2_E84流程异常,OHT_TR_REQ_ON信号超时",请检查OHT或者E84线缆
52,EFEM,151,0,0,1051,"Port2_E84流程异常,OHT_BUSY_ON信号超时",请检查OHT或者E84线缆
53,EFEM,152,0,0,1052,"Port2_E84流程异常,OHT_COMPT_OFF信号超时",请检查OHT信号或者E84线缆
54,EFEM,153,0,0,1053,,
55,EFEM,154,0,0,1054,,
56,EFEM,155,0,0,1055,,
57,EFEM,156,0,0,1056,,
58,EFEM,157,0,0,1057,,
59,EFEM,158,0,0,1058,,
60,EFEM,159,0,0,1059,,
61,EFEM,160,0,0,1060,"Port2_E84流程停止,OHT_VALID信号异常",请检查OHT信号或者E84线缆
62,EFEM,161,0,0,1061,"Port2_E84流程停止,光栅被遮挡或者急停被拍",请检查光栅信号急停
63,EFEM,162,0,0,1062,"Port2_E84流程停止,OHT_取或放FOUP超时","OHT_BUSY后未在规定时间内取走FOUP,请检查OHT或者核对LP状态"
64,EFEM,163,0,0,1063,"Port2_E84流程停止,OHT_BUSY_OFF或者TR_REQ_OFF信号超时",请检查OHT信号或者E84线缆
65,EFEM,164,0,0,1064,,
66,EFEM,165,0,0,1065,,
67,EFEM,166,0,0,1066,,
68,EFEM,167,0,0,1067,,
69,EFEM,168,0,0,1068,,
70,EFEM,169,0,0,1069,,
71,EFEM,170,1,0,1070,,
72,EFEM,171,1,0,1071,"Port3_E84流程停止,OHT_VALID信号异常",请检查OHT信号或者E84线缆
73,EFEM,172,1,0,1072,"Port3_E84流程停止,光栅被遮挡或者急停被拍",请检查光栅信号急停
74,EFEM,173,1,0,1073,"Port3_E84流程停止,OHT_取或放FOUP超时","OHT_BUSY后未在规定时间内取走FOUP,请检查OHT或者核对LP状态"
75,EFEM,174,1,0,1074,"Port3_E84流程停止,OHT_BUSY_OFF或者TR_REQ_OFF信号超时",请检查OHT信号或者E84线缆
76,EFEM,175,1,0,1075,,
77,EFEM,176,1,0,1076,,
78,EFEM,177,1,0,1077,,
79,EFEM,178,1,0,1078,,
80,EFEM,179,1,0,1079,,
81,EFEM,180,1,0,1080,"Port3_E84流程异常,OHT_TR_REQ_ON信号超时",请检查OHT或者E84线缆
82,EFEM,181,1,0,1081,"Port3_E84流程异常,OHT_BUSY_ON信号超时",请检查OHT或者E84线缆
83,EFEM,182,1,0,1082,"Port3_E84流程异常,OHT_COMPT_OFF信号超时",请检查OHT信号或者E84线缆
84,EFEM,183,1,0,1083,,
85,EFEM,184,1,0,1084,,
86,EFEM,185,1,0,1085,,
87,EFEM,186,1,0,1086,,
88,EFEM,187,1,0,1087,,
89,EFEM,188,1,0,1088,,
90,EFEM,189,1,0,1089,,
91,EFEM,190,1,0,1090,,
92,EFEM,191,1,0,1091,"Port4_E84流程停止,OHT_VALID信号异常",请检查OHT信号或者E84线缆
93,EFEM,192,1,0,1092,"Port4_E84流程停止,光栅被遮挡或者急停被拍",请检查光栅信号急停
94,EFEM,193,1,0,1093,"Port4_E84流程停止,OHT_取或放FOUP超时","OHT_BUSY后未在规定时间内取走FOUP,请检查OHT或者核对LP状态"
95,EFEM,194,1,0,1094,"Port4_E84流程停止,OHT_BUSY_OFF或者TR_REQ_OFF信号超时",请检查OHT信号或者E84线缆
96,EFEM,195,1,0,1095,,
97,EFEM,196,1,0,1096,,
98,EFEM,197,1,0,1097,,
99,EFEM,198,1,0,1098,,
100,EFEM,199,1,0,1099,,
101,EFEM,200,1,0,1100,"Port4_E84流程异常,OHT_TR_REQ_ON信号超时",请检查OHT或者E84线缆
102,EFEM,201,1,0,1101,"Port4_E84流程异常,OHT_BUSY_ON信号超时",请检查OHT或者E84线缆
103,EFEM,202,1,0,1102,"Port4_E84流程异常,OHT_COMPT_OFF信号超时",请检查OHT信号或者E84线缆
104,EFEM,203,1,0,1103,,
105,EFEM,204,1,0,1104,,
106,EFEM,205,1,0,1105,,
107,EFEM,206,1,0,1106,,
108,EFEM,207,1,0,1107,,
109,EFEM,208,1,0,1108,,
110,EFEM,209,1,0,1109,,
111,EFEM,210,0,0,1110,回原点失败/超时,请检查设备状态以及轴位置是否有干涉,请重新执行回原操作
112,EFEM,211,0,0,1111,Flip工位,真空打开时在荷异常,请检查玻璃位置
113,EFEM,212,1,0,1112,,
114,EFEM,213,1,0,1113,,
115,EFEM,214,1,0,1114,,
116,EFEM,215,1,0,1115,,
117,EFEM,216,1,0,1116,,
118,EFEM,217,1,0,1117,,
119,EFEM,218,1,0,1118,,
120,EFEM,219,1,0,1119,,
121,EFEM,220,1,0,1120,任务取消失败,当前取消任务条件不满足
122,EFEM,221,1,0,1121,任务重试失败,当前重试任务条件不满足
\ No newline at end of file

--